Applicable to:
KV-25FX20B RM-887 French SCC-Q33B-A
KV-25FX20D RM-887 AEP SCC-Q31B-A
KV-25FX20E RM-887 Spanish SCC-Q34B-A
KV-25FX20K RM-887 OIRT SCC-Q36C-A
KV-25FX20R RM-887 OIRT SCC-Q36D-A
KV-29FX20A RM-887 Italian SCC-Q32A-A
KV-29FX20B RM-887 French SCC-Q33A-A
KV-29FX20D RM-887 AEP SCC-Q31A-A
KV-29FX201D RM-887 AEP SCC-Q31E-A
KV-29FX20E RM-887 Spanish SCC-Q34A-A
KV-29FX201E RM-887 ESP SCC-Q34E-A
KV-29FX20K RM-887 OIRT SCC-Q36B-A
KV-29FX20R RM-887 OIRT SCC-Q36A-A
KV-29FX20U RM-887 UK SCC-Q35A-A
SELF DIAGNOSTIC
SOFTWARE
The
identification of errors within the FE-1A chassis is triggered in one of two
ways :- 1: Busy or 2: Device failure to respond to IIC. In the event of one of
these situations arising the software will first try to release the bus if busy
(Failure to do so will report with continuous flashing LED) and then
communicate with each device in turn to establish if a device is faulty. If a
device is found to be faulty the relevant device number will be displayed
through the LED (Series of flashes which must be counted) See Table 1., non
fatal errors are reported using this method.
Each time the software
detects an error it is stored within the NVM.
How to enter into Table 2
1. Turn on the main power switch of the TV set and enter into the ‘Standby
Mode’.
2. Press the following sequence of buttons on the Remote Commander.
3. The following table will be displayed indicating the error count.
Semiconductors bases
IC BLOCK DIAGRAMS