LG WD-1247 BD WASHING MACHINE-Error codes, troubleshooting, fault diagnosis, wiring and program chart

 

CHILD LOCK

Use this option to prevent unwanted use of the washer. Press and hold the Wash and Rinse button for 3 seconds to lock/unlock control.

When Child lock is set, CHILD LOCK lights and all buttons are disabled except the Power button. You can lock the washer while it is operating.

Test operation

SERVICE CHECKING

Be careful of electric shock or disconnecting the parts while trouble shooting.

Voltage of each terminal is 220-240V~ and DC while applying an electric current.

TEST MODE

Pressing Rinse, and Spin button simultaneously.

Press the Power button, while the above condition.

Press the Start/Pause button as follows.


HOW TO KNOW THE WATER LEVEL FREQUENCY and HOW TO KNOW TO TEMPERATURE OF EACH THERMISTOR AT OPERATING CONDITION.

Temperature of each thermistor at operating condition

Thermistor in tub : Press the [Temp.] button.

 Thermistor in dry duct : Press the [Turbo Steam] button.

WIRING DIAGRAM and PROGRAM CHART

ERROR DISPLAY

If you press the Start/Pause button in error condition, any error except “PE” will disappear and the machine will change into pause status.

In case of  [PE, TE, dHE] if the error is not resolved within 20 sec., and in case of other errors, if the error is not resolved within 4 min., power will be turned off automatically and the error only will be blinked. But in case of  , [FE] power will not be turned off.

FAULT DIAGNOSIS AND TROUBLE SHOOTING

Be careful of electric shock or disconnecting the parts while trouble shooting.

First of all, check the connection of each part terminal with wiring diagram.

If you replace the MAIN PWB ASSEMBLY, Put in the connectors correctly.