Wednesday, 5 May 2021

TCL PWL3711C, and PWL3708B, ON37A switch Mode power supply Switch Power Supply schematic and troubleshooting

 

AC Input and EMI Filtering Circuit
PWL3711C power supply is composed of anti-interference circuit, bridge commutation circuit, filter circuit, PFC( Power factor Correction) circuit and switch stabilized voltage circuit and so on. The merits of switch power supply are wide operation voltage, low power consumption, high power reaching over 98%.  It has many protection functions such as OCP, OVP and over heat protection.

The switch power supply has two operation conditions:
1) Normal-Normal work when power on;
2) Standby-When TV set standby, switch power supply is in narrow pulse operation condition and change to under voltage condition, then the output voltage goes down to half value of normal condition;
The theory introduction of each part of the switch power supply as following:
I Anti-interference circuit
When switch on, the commercial AC220V/50Hz passes common-mode filter composed of fuse F1
,ZV1,R1,CX1,CX, LF1, LF2 to eliminate the all the EMI and high frequency interference pulse from power input port.
X capacity and Y capacity are both safety capacitance. The difference of them is that X capacitance is connected to AC input port to eliminate difference-mode interference, Y capacitance is connected between AC input and ground to eliminate common-mode interference. Y capacitance has two kinds, one is Y1 capacitance belonging to double insulation Y capacitance and connecting between primary coil and second coil, the other is Y2 capacitance belonging to basic single insulation Y capacitance and connecting between primary coil to protect ground.

Commutating Filter Circuit
BD1,C1,C2 compose bridge commutating circuit to convert the 220 AC to 300 DC filtered by C3.

PFC Circuit
PFC circuit is composed of IC1(NCP1650),Q1,L2 and the other external components.
NCP1650 Power Factor Controller Introduction
NCP1650 chip is an active, power factor correction controller that can operate over a wide range of input voltages, and output power level. It is designed to operate on 50/60Hz power system. This controller offers severl different protection methods to assure safe, reliable operation under any conditions.
Feature:
Fixed Frequency Operation
Average Current Mode PWM
Continuous or Discontinuous Mode
Operation
Fast Line/Load Transient Compensation
True Power Limiting Circuit
High Accuracy Multipliers
Undervoltage Lockout
Overvoltage Limiting Comparator
Brown Out Protection
Ramp Compensation Does Not Affect
Oscillator Accuracy
Operation from 25 to 250kHz
PFC circuit of PWL3711C is fixed frequency average current mode boost converter. PFC circuit operates in two stages: 90Vac
132Vac is the low input stage for PFC output 260VDC;180Vac264Vac is high input stage for PFC output 390VDC. The shift stage is 140Vac 165Vac completed by comparator IC10. When input commercial current in high stage, the level of pin 3 of IC10 is higher than pin2, then Q21 turns on to make sample voltage of IC1 FB(pin6) go down and make the output voltage of PFC go up to 390VDC.

The operation frequency is about 70KHz.The output current changing should follow input voltage changing to go to pin5/pin12 of IC and the voltage entering pin6 of IC. When the inner parameters are compared and calculated to confirm the operation duty ratio and maintain the stabile voltage. Under the stable output power, the input voltage decrease, minimum duty ratio of the output pulse width of IC1 largen. When input voltage increases, the minimum duty ratio of pulse width output will decrease; vice versa.

In an output cycle, duty ratio of IC1 pulse width output is mutative in which there is a minimum duty ratio on the highest point of Vac.  Q1 alternating with D1 produce output current of bridge commutating diode to flow continuously, and the angle of flow go to 180° so that the current of AC has the same phase with voltage of AC . The waveform is sine wave, and the power factor of system should approach to 1

DC-DC Shift:
12V Section
IC6-NCP1377
NCP1377 PWM Current-Mode Power Supply Controller
NCP1377 combines a true current mode modulator and a demagnetization detector which ensures full borderline/critical Conduction Mode in any load/line conditions together with minimum drain voltage switching. Due to its inherent skip cycle capability, the controller enters burst mode as soon as the power demand falls below a predetermined level. As this happens at low peak current, no audible noise can be heard.
The transformer core reset detection is done through an auxiliary winding which, brought via a dedicated pin, also enables fast Over Voltage Protection. Once an OVP has been detected, the IC permanently latches-off. The 1377 features a sampling time of 4.5us whereas it is 1.5us for the B version.
The NCP1377 also features an efficient protective circuitries which, in presence of an overcurrent condition, disables the output pulse and enters a safe burst mode, trying to restart.
Once the default has gone, the device auto-recovers. Finally an internal 1.0 ms soft-start eliminates the traditional startup stress.
 Features
Free-running borderline/critical mode quasi-resonant operation
Lockout OVP
Auto-recovery short-circuit protection via UVLO crossover
External latch triggering, e.g. via overtemperature signal
Current-mode with adjustable skip-cycle capability
Internal 1.0 ms soft-start
Internal temperature shutdown
Internal leading edge blanking
500mA peak current source/sink capability
Under voltage lockout level of 12.5V  On and 7.5V Min

Direct optocoupler connection

NCP 1377 test parameters

Pin

Red probe to ground

Voltage

1

13K

0

2

41K

0

3

1K

0

4

0

0

5

3K

0

6

30Ω

10V

7

0

8

400K

350V

Pin8 of IC6 connects R101 to “+”end of C16 via internal 4mA constant-current source to charge C34. When reaches about 12.5V, output of pin5 of IC6 is pulse width waveform and 4mA constant-current sourse will shut off, then auxiliary winding of transformer T2 supplies C34.
Because of PFC circuit, voltage of C16 is constant, and the changing of duty ratio of IC6 is only with output load. At the moment of output loads enhance, 12V drops and the current of IC8 reduces, then level of pin12 of IC6 goes up, so largens pulse width duty ratio of IC6 and makes the turn-on time longer to make transformer transmit more energy. Output of 12V goes up to largen turn-on current of IC8. 
In fact, under output load changeless, IC6 also performs the above adjustment, but the adjustment amplitude is slight. Output constant voltage relies to above closed loop adjustment, so that forms output voltage ripple form

24V Section
24V branch section is basic sameness to 12V section, but only little difference in function of IC NCP1217(IC2) is current mode PWM controller, applying to offline switch power supply.
Feature
Current-mode with adjustable skip-cycle capability
Built-in internal ramp compensation
Auto-recovery internal output short-circuit protection
Internal 1.0ms soft-start
Fixed frequency versions at 65kHz, 100kHz and 133kHz
Pin function description

Pin No

Symbol

Function

1

Adj

Adjust the skipping peak current

2

FB

Sets the peak current setpoint

3

CS

Current sense input

4

Gnd

IC Ground

5

Drv

Drive pulse

6

VCC

supplies the IC

7

NC

8

HV

Ensures a clean and lossless startup sequence

Internal Circuit architecture

Switch Voltage Regulated Circuit:  Power Supply DC Output
24V/4A power supply branch: One way goes directly to primary winding passing primary winding 1-3 to pin D of Q2/ Q17; the other way passing D3 and goes directly to pin8 of IC2 connecting internal circuit of IC to pin6 to charge C21. When the voltage setpoint reaches 12.5V, IC2 operates normally and internal circuit latches off between pin6 and pin8, then C21 discharges through internal circuit of IC2. At the same time, output of pin5 is driving signal to Q2/Q17 which turns on, so the primary winding of T1 turns on to store the energy.
When C21 discharge to 5.6V, the discharge circuit shuts off and driving signal of pin5 latches off , so each secondary winding of T1 induces output voltage via to energy shift.
At the same time, secondary winding pin6 charges C21 through L5/D7, when reaching 12.5V, pin5 of IC2 sends out drive signal to Q2 and Q17 which turns on, so primary winding of T1 turns on to enter new save energy loop process and ensure inducing constant output voltage from each secondary winding.
When output of secondary reaches over 24V, the current of photocoupler IC3 enhances as R24 sample voltage largens, so that photo coupler shines strongly to feedback to pin2 of IC2, the point voltage of this pin going low. Output signal of pin5 of IC2 shuts off to adjust duty ratio.
12V/4A power supply branch: One way to primary winding 1-3 of T2, then to D pin of Q5; the other way via D11 to pin8 of IC6(NCP1377), connecting internal circuit of IC6 to charge C34, when voltage of C34 reaches 12.5V, IC6 starts up to operation, and the internal circuit disconnects from pin6 and pin8. C21 discharges via internal circuit of IC6, and pin5 exports drive signal to make Q5 turns on, so connects primary winding of T2, and T2 starts saving energy.
When C21 discharges to 5.6V, the discharge circuit will shut off, and output drive signal will stop from pin5. For energy shift, inducing output voltage produces from each secondary winding of T2.
At the meantime, secondary winding pin6 charges C34 via D13/R37, when the voltage reaches 12.5V to drive pin5 to export drive signal, Q5 turns on and connects primary winding of T2, then renews to save energy to ensure constant inducing output voltage from each secondary winding.
When output voltage of secondary winding reaches 12V, the current of passing photocoupler IC8 enhance, so the photocoupler shines strongly to feedback to pin2 of IC6, the level of this pin goes down to output signal of pin5 of IC6 shuts off to adjust duty ratio to ensure constant output voltage 12V

Over-Current Protection: 24V/4A supply power branch
The sample current passes R20 to get the sample voltage which on R17 to connect internal circuit of pin3 of IC2. When the sample current reaches a certain rated value, IC2 stops to work and protects the circuit.
12V/4A supply power branch
The sample current passes R39 to get sample voltage which is on R42 to connect internal circuit of IC6’s pin3. When the sample current reaches a certain rated value, IC6 would stop to work to protect the circuit.
OVP Circuit
12V/4A Supply Power Branch
Secondary winding pin5 of T2 connects IC6’s pin1 via R35, when testing circuit of IC6 test the voltage over the rated value, IC6’s pin5 stops to export drive signal to make Q5 shut off.
When canceling the test signal, IC6’s pin5 exports drive signal again to make Q5 turn on and continue to operate
24V/6A Supply Power Branch
when the output is higher than 31V, so ZD2 and ZD3 work normally and signal 24V-OVP is high level. Q3
s pinC connects to ground. The current between pin1and pin2 of IC3, so inner diode shines strongly, the current largen between pin3 and pin4. This signal is sent to pin2 of IC2 to latch off the drive signal. The power is off.When the high level signal 24V-OVP is sent to pinB of Q12, Q12 turns on to the ground. The photo coupler is shines strongly and the current of receiver increases. So the low level is sent to pin8 of IC2 to shut off the power.

Power Standby
When plug in AC commercial current, the 12V of power supply continues to operate, power supply standby circuit control is only for 24V supply.
Remote control signal connect P2’s pin1 via J2’s pin4 to passing R33 to B pin of Q4. When receives power on signal, the B pin of Q4 is low level, Q4 turns on and Q12 shuts off.

Power off: when receives the remote signal low, Q4 shuts off and Q12 turns on. Because of induction action of photocoupler, the level of IC2’s pin2 is pulled low, so IC2 stops to operate
Power on: when receives power on high level signal, Q4 turns on and B pin of Q12 equals to connect ground. For photocoupler doesn’t work, IC2’s pin2 releases and this setpoint voltage is high level. IC2 renews to operate to export drive signal from pin5, so the circuit exports 24V power supply.

Trouble Shooting: No Power

There are two supply outputs: +12V and + 24V by different transformer in this power supply solution. When TV switch on, +12V output is ok to all the boards; then send standby signal to power on, +24V output to the panel.
If HV is higher than130V, but High and Low Voltage Converter Circuit don’t work, +12V and +24V output will be still ok.

No +12V, No +24V trouble shooting

No +12V, No +24V trouble shooting

No +12V, No +24V trouble shooting

+12V OK, No +24V trouble shooting

Repairing
1) A 40W bulb is necessary to be connected between the AC lines and lest the power board damaged.
The bulk will twinkle if the PWB is good. The input power is about several decades Watt. You can measure 12V and 24V can be measured when P-ON voltage is given or connected with 12V;If the bulb is lightening and no output is detected, the PWB still need further repairing.
2
) Possible defective cause: defective Design defective Material Producing engineering problem: short circuit(soldering-connected, pin-shorted),open-circuit(false soldering, pin-unconnected)
3
) Troubleshooting steps: If the fuse is OK and no output, IC is possibly damaged or shut down under protective status. The other side, if the fuse is broken, you should check more parts like IC, MOSFET, Diodes, Zener diode etc. You should know the pin functions of IC Checking IC2 and IC6, 13V DC supply to VCC with no AC input. Test the voltage of PIN2 if the voltage is 4.2VDC or not, and test if the output pulse width decrease or not by an oscilloscope. If not, replace the IC.
4)
Holes of double-face board , small copper wire will easy open when the power board pass oven ,it’s not easy to be found, the places where is easy open are MOSFET S pole to grounding, drive circuit and ISENCE circuit.
5
) Component check: transformer /inductance /photo coupler /TL431 on the power board aren’t easy to damage , most MOSFET damage is like G-S short circuit ,G-D-S short circuit, even crack, most transistors damage are as B-E short circuit, C-B-E short circuit even crack., diode damage is as short circuit. Zener diode damage is open circuit even crack. IC2 damage is possible ground to output(D1) short circuit or less than 0.5; ground to VCC(D1)short circuit or less than 0.5 even crack.
Resistor damage is the resistance value increase even crack. SMD Capacitor damage is crack or capability too large ; electrolytic capacitance damage is crack, plump , electrolyte leakage 

PWL3711C SMPS schematic

PWL3708B-SMPS and PWL3711C

The theory of these two switch power supply can refer to the description of LCD3711c.

ON37A switch power supply
About ON37A Power Supply
ON37A power supply circuit was designed by TCL R&D center, The circuit adopt PFC control IC NCP1653 and PWM control IC NCP1377,it has over voltage protection, over current protection ,over hot protection function etc. IC’s Follow Boost pattern can increase whole circuit efficiency at low voltage, increase dependable stability, and it can eliminate noise on some point of load, it make the unit’s performance more steady.


Schematic diagram – PWL3708B



Vestel 17 PW26, Vestel 17 IPS60, JOCEL JT 37N6 CRT TV - SCHEMATIC DIAGRAM

 VESTEL 17PW26 SCHEMATIC DIAGRAM

VESTEL 17IPS60 SCHEMATIC DIAGRAM

JOCEL 37N6 CRT TV SCHEMATIC DIAGRAM


Tuesday, 4 May 2021

Toshiba 32L2800, L32-40-43-49S4900FS NT63 Power board schematic, software upgrade, amp section circuit diagram

 

CHECKING THE SOFTWARE VERSION.

- With the TV on enter the Factory menu

- In the Factory menu, check if the software version installed is correct.

Main SW update via the User Menu

- Download the compressed file update.zip, change the name and extension to “V8-N563T01-LF1Vxxx.bin” where xxx is the version number.

- Save the file to the root of a USB device.

- Connect the USB device, with the software, to the USB port.

- Select MENU Support Update. of ware via USB.

- The device will find the Vxxx software. Press “Update”

- The update will start. After approximately 4 minutes the TV will automatically restart.

- After restarting, perform the reset by going to the settings menu “MENU (key) System Restore Mode

Factory. Confirmation and password request is requested. Enter 1234 and press "OK".

- After this the TV will restart.

Note: The version of the So ware to be used must be the one informed in the material plan of the respective product.

After approximately 4 minutes the TV will automatically restart.



UPDATE WHEN THE APPLIANCE HAS NO VIDEO

- Save the file to the root of a USB device by renaming it as “update.zip”.

- With the device disconnected from the mains, connect the USB device, with the installation software, to the USB port.

- Press the TV's Power key and keeping it pressed, connect the TV to the mains

- The update will start. After approximately 4 minutes the TV will automatically restart.

- After restarting, perform the reset by going to the settings menu “MENU (key) System Restore Mode

Factory. Confirmation and password request is requested. Enter 1234 and press "OK".

- After this the TV will restart.

PROJECT ID CHANGE

(If panel information is wrong)

If the screen is completely dark due to the difference in panel x installed ware, press 062598 + MENU + xxx (xxx: Panel ID)


After the update, the TV will enter TV mode and the channel that was previously selected. Enter the menu factory settings again, select option 3 - Reset Shop, press enter.

After the reset, switch on the device using the power key.

PANEL TEST MODE (WARM-UP)

Recommended for analysis of panels (spots, dots, scratches, etc.).

Enter the Factory Menu as indicated before, turn on the "Factory hotkey" option and turn on the "WARM-UP" function.

A sequence of screens in different colors will be generated where it can be verified in more detail, possible failures the panel.


VERIFICATION OF AUTHENTICATION KEYS

In the same “WARM-UP” mode, a table with the main product information will be displayed in the corner bottom right.

In this table we have the project information:

We have the project ID, as shown in the table above and then the version of the software in use.

Below the information of the recorded keys (MID):

MAC (Mac Address) Without recording this key, it is not possible to connect to the internet network via ethernet (LAN);

DID (Device ID) Factory Control of the product; Already included in the main ware.

ESN (Ne lix) Without the recording of this key, it will not be possible to access the Ne lix services;

HDCP Without recording this key, high definition images from the HDMI inputs will not be reproduced;

HDCP2.0 Without the recording of this key, high definition images via wireless will not be reproduced;

IMPORTANT NOTE: If some of the keys are not recorded, the information “NULL” will appear in substitution the respective key in that line as shown in the image on the right.

In this case, SEMP TCL support should be contacted for instructions on recording procedures.

To EXIT the “WARM-UP” mode, press the POWER key on the device because the control functions remote will be disabled and if the device is just disconnected from the network, the “WARM-UP” mode will return when connected to the network again.

After exiting WARM-UP, enter the factory menu again and turn off the Factory Hotkey option or give a user reset.


Power board schematic

ENTRY STAGE

CONVERTING STEP

BACKLIGHT CONTROL STEP

AMP USING  AD82587

PHONES OUTPUT - AMP AND CONNECTIONS


Tuesday, 20 April 2021

TNPA6397EC Panasonic KM32 Power supply board for Panasonic TX-43FX623 LCD TV - LCD TV POWER SUPPLY, INVERTER

 

Panasonic LCD TVs -TH-43EX600T, TX-43FX600B, TX-49FX600B, TX-49FX600E, TX-49FX650B, TX-43FX600E, TX-43FXW654, TX-43FX650B, TH-43EX600

Used Ics - IC7201: FA5696N-C6-TE3, IC7301: FA6B02N-C6-L3, IC7401: MM1431GNRE, IC7405: BD9E102FJ-GE2, IC7800: BD9486F-GE2







Thursday, 15 April 2021

Philips 40PFA4509, 50PFA4509 Chassis-service mode, power supply schematic - A715G6297, A715G6197

 

Philips 24PHA4309 / 56/98, 24PHA4309S / 98, 24PHA4509 / 98/56, 24PHA4509S / 98, 24PHA4309S / 40, 32PHA4509 / 56/98, 32PHA4509S / 98/40, 32PHT5109 / 56/98, 32PHT5109S / 98, 40PFA4509 / 56/98, 40PFA4509S / 98/40, 50PFA4509S / 98 / 40, 50PFA4509 / 56/98, 58PFT5309S / 40

Alternative BOM identification
It should be noted that on the European Service website, “Alternative BOM” is referred to as “Design variant”.
The third digit in the serial number (example: AG2B0335000001) indicates the number of the alternative B.O.M. (Bill Of Materials) that has been used for producing the specific TV set. In general, it is possible that the same TV model on the market is produced with e.g. two different types of displays, coming from two different suppliers. This will then result in sets which have the same CTN (Commercial Type Number; e.g. 28PW9515/12) but which have a different B.O.M. number.
By looking at the third digit of the serial number, one can identify which B.O.M. is used for the TV set he is working with.
If the third digit of the serial number contains the number “1” (example: AG1B033500001), then the TV set has been manufactured according to B.O.M. number 1. If the third digit is a “2” (example: AG2B0335000001), then the set has been produced according to B.O.M. no. 2. This is important for ordering the correct spare parts.
For the third digit, the numbers 1...9 and the characters A...Z can be used, so in total: 9 plus 26= 35 different B.O.M.s can be indicated by the third digit of the serial number.

Identification: The bottom line of a type plate gives a 14-digit serial number. Digits 1 and 2 refer to the production centre (e.g.SN is Lysomice, RJ is Kobierzyce), digit 3 refers to the B.O.M. code, digit 4 refers to the Service version change code, digits 5 and 6 refer to the production year, and digits 7 and 8 refer to production week (in example below it is 2010 week 10 / 2010 week 17). The 6 last digits contain the serial number.



Board Level Repair (BLR) or Component Level Repair (CLR)
If a board is defective, consult your repair procedure to decide if the board has to be exchanged or if it should be repaired on component level.
If your repair procedure says the board should be exchanged completely, do not solder on the defective board. Otherwise, it cannot be returned to the O.E.M. supplier for back charging.

Service Positions
For easy servicing of a TV set, the set should be put face down on a soft flat surface, foam buffers or other specific workshop tools. Ensure that a stable situation is created to perform measurements and alignments. When using foam bars take care that these always support the cabinet and never only the display. Caution: Failure to follow these guidelines can seriously damage the display.
Ensure that ESD safe measures are taken.

Service Modes and Fault Finding

Service Modes
The Service Mode feature is split into five parts:
• Factory Mode.
• Customer Service Mode (CSM).
The Factory mode offer features, which can be used by the Service engineer to repair/align a TV set. Some features are:
• Make alignments (e.g. White Tone), reset the error buffer
(Factory Mode).
The CSM is a Service Mode that can be enabled by the consumer. The CSM displays diagnosis information, which the customer can forward to the dealer or call centre. In CSM mode, “CSM”, is displayed in the top right corner of the screen.
The information provided in CSM and the purpose of CSM is to:
• Increase the home repair hit rate.
• Decrease the number of nuisance calls.
• Solved customers’ problem without home visit.
Note: For the new model range, a new remote control (RC) is used with some renamed buttons. This has an impact on the activation of the Service modes. For instance the old “MENU” button is now called “HOME” (or is indicated by a “house” icon).

Software Identification, Version, and Cluster
The software ID and version will be shown in the main menu display of CSM.
The screen will show: “AAAAB-X.YYY”, where:
• AAAA is the chassis name: TPS141A x.yyy.
• B is the region indication: E = Europe, A = AP/China, U = NAFTA, L = LATAM.
• X is the main version number: this is updated with a major change of specification (incompatible with the previous software version). Numbering will go from 1 - 99 and AA - ZZ.
- If the main version number changes, the new version number is written in the NVM.
- If the main version number changes, the default settings are loaded.
• YYY is the sub version number: this is updated with a minor change (backwards compatible with the previous versions). Numbering will go from 000 - 999.
- If the sub version number changes, the new version number is written in the NVM.
- If the NVM is refreshed, the software identification, version, and cluster will also be written to NVM.

How to Activate the Factory mode
To activate the Factory mode, use the following method:
• Press the following key sequence on the remote control transmitter: from the
“Home screen” press “1999”, directly followed by the “Back” button. Do not allow the display to time out between entries while keying the sequence.
After entering the Factory mode, the following items are displayed,

Factory mode overview


How to Exit the Factory mode
Use one of the following methods:
• Select EXIT_FACTORY from the menu and press the “OK” button.
Note: When the TV is switched “off” by a power interrupt, or normal switch to “stand-by” while in the factory mode, the TV will show up in “normal operation mode” as soon as the power is supplied again. The error buffer will not be cleared.

Customer Service Mode (CSM)
Purpose
The Customer Service Mode shows error codes and information on the TV’s operation settings. The call center can instruct the customer (by telephone) to enter CSM in order to identify the status of the set. This helps the call center to diagnose problems and failures in the TV set before making a service call.
The CSM is a read-only mode; therefore, modifications are not possible in this mode.
Specifications
• Ignore “Service unfriendly modes”.

• After leaving the Customer Service Mode, the original settings are restored.

• Possibility to use “CH+” or “CH-” for channel surfing, or enter the specific channel number on the RC.
How to Activate CSM
To activate CSM, press the following key sequence on a standard remote control transmitter:
“456987” (do not allow the display to time out between entries while keying the sequence).
After entering the Customer Service Mode, the following items are displayed.
Note: Activation of the CSM is only possible if there is no (user) menu on the screen

Contents of CSM
Set Type This information is very helpful for a helpdesk/workshop as reference for further diagnosis. In this way, it is not necessary for the customer to look at the rear of the TV-set. Note that if an NVM is replaced or is initialized after corruption, this set type has to be re-written to NVM.
Production code Displays the production code (the serial number) of the TV. Note that if an NVM is replaced or is initialized after corruption, this production code has to be re-written to NVM.
HDCP keys Indicates the validity of the HDMI keys (or HDCP keys). In case these keys are not valid and the customer wants to make use of the HDMI functionality, the SSB has to be replaced.

NVM name Detects and displays NVM name.
Software Version Displays the software version.
RS232 Display RS232.
TV Region Display TV region.
LCD display panel 12NC NVM read/write.
SSB Gives an identification of the SSB as stored in NVM. Note that if an NVM is replaced or is initialized after corruption, this identification number has to be re-written to NVM. This identification number is the 12NC number of the SSB.
PSU 12NC NVM read/write.
How to Exit CSM
To exit CSM, use one of the following methods.
• Press the MENU/HOME button on the remote control transmitter.
• Press the POWER button on the remote control transmitter.
• Press the POWER button on the television set.

Reset of Repaired SSB [Small Signal Board]
A very important issue towards a repaired SSB from a Service repair shop (SSB repair on component level) implies the reset of the NVM on the SSB.
After a repaired SSB has been mounted in the set (set repair on board level), the type number (CTN) and production code of the TV has to be set according to the type plate of the set.

SSB Identification
SSB’s of this chassis are identified by a “715” code on the SSB.
715Axxxx-Nnn-MMM-OOOO
715 main category, Printed Wiring Board
Axxxx sub category, sequential coding number
Nnn Version code
N Development number
• nn Production number
MMM Mounting variation code
OOOO Optional variation code
Make sure when replacing an SSB the SSB identification codes match the replacement board.


Power Supply Unit
All power supplies are a block box for Service. When defective, a new board must be ordered and defective one must be returned,unless the main fuse of the board is broken. Always replace a defective fuse with one with the correct specifications. This part is available in the regular market.
Consult the Philips Service web portal for the order codes of the boards.
Important delta’s with the TPS14.1A LA classis platform are:
• New power architecture for LED backlight
• “Boost” signal is now a PWM-signal + continuous variable.
The control signals are:
• Stand-by
• Lamp “on/off”
• DIM (PWM) (not for PSDL)
In this manual, no detailed information is available because of design protection issues.
The output voltages to the chassis are:
• +4V7-STANDBY (Stand-by mode only)
• +12V (on-mode)
• +Vsnd (+24V) (audio power) (on-mode)
• +24V (bolt-on power) (on-mode)

Output to the display; in case of
- IPB: High voltage to the LCD panel
- PSL and PSLS (LED-driver outputs)
- PSDL (high frequent) AC-current.

Diversity
The diversity in power supply units is mainly determined by the diversity in displays.
The following displays can be distinguished:
• CCFL/EEFL backlight: power board is conventional IPB
• LED backlight:
- side-view LED without scanning: PSL power board
- side-view LED with scanning: PSLS power board
- direct-view LED without 2D-dimming: PSL power board
- direct-view LED with 2D-dimming: PSDL power board.
PSL stands for Power Supply with integrated LED-drivers.
PSLS stands for a Power Supply with integrated LED-drivers with added Scanning functionality (added microcontroller).
PSDL stands for a Power Supply for Direct-view LED backlight with 2D-dimming.


DC/DC Converters
The on-board DC/DC converters deliver the following voltages (depending on set execution):
• +5V-STANDBY, permanent voltage for the Stand-by controller
• +3V3-STANDBY, power supply for LED/IR receiver and controls
• +12V, input from the power supply for the panel common (active mode)
• +24V, input from the power supply for the amplifier
• +1V2, from the power supply for the scaler IC MST6931
• +1V8, supply voltage for DDR2 (diagram B03B) • +3V3, general supply voltage
• +3.3V-TUN, supply voltage for tuner
• +3.3V, supply voltage for Headphone AMP
• +5V-USB, input intermediate supply voltage for USB Power
• +3V3 from the power supply for the scaler IC MST6931

A 715G6197 PSU – schematic



A 715G6297 PSU – schematic




Sunday, 21 March 2021

Panasonic DMR E55PL DVD and Panasonic DMR ES10P, Panasonic DMR ES10PC - Video Recorder power board schematic diagram (Circuit Diagram)

 

Panasonic DMR E55PL DVD Video Recorder power board schematic diagram (Circuit Diagram)

Used Ics: STRG6353, PS2571-Photo Coupler, TL431ALPR-Switching IC



Panasonic DMR ES10P, Panasonic DMR ES10PC Power board schematic diagram (circuit diagram)

This model’s DVD drive is VSX 1867.

Used Ics: CODACZH00022 (Switching IC), C0DBAKG00007 (DC-DC converter), B1DHDD000022 (REG +1.5v), B1DHDD000022 (REG.XSW+3.8V), C0DAZJH00003 (REG.DR+12V), C0CBCYG00004 (REG.DR+5V), B3PBA0000023 (Photo Coupler)




LG 52LG50FD, 52LG50FD-SA-Service adjustments-service mode entry-white balance adjustment-ADC component 1 RGB adjustment and more

  These adjustments are similar to 42LB7DF Because this is not a hot chassis, it is not necessary to use an isolation transformer. However...