CHECKING THE SOFTWARE
VERSION.
- With the TV on enter the Factory
menu
- In the Factory menu, check if the
software version installed is correct.
Main SW update via the
User Menu
- Download the compressed file
update.zip, change the name and extension to “V8-N563T01-LF1Vxxx.bin” where xxx
is the version number.
- Save the file to the root of a USB
device.
- Connect the USB device, with the
software, to the USB port.
- Select MENU Support Update. of ware
via USB.
- The device will find the Vxxx
software. Press “Update”
- The update will start. After
approximately 4 minutes the TV will automatically restart.
- After restarting, perform the reset
by going to the settings menu “MENU (key) System Restore Mode
Factory. Confirmation and password request
is requested. Enter 1234 and press "OK".
- After this the TV will restart.
Note: The version of the So ware to be
used must be the one informed in the material plan of the respective product.
After approximately 4 minutes the TV
will automatically restart.
UPDATE WHEN THE
APPLIANCE HAS NO VIDEO
- Save the file to the root of a USB
device by renaming it as “update.zip”.
- With the device disconnected from
the mains, connect the USB device, with the installation software, to the USB
port.
- Press the TV's Power key and keeping
it pressed, connect the TV to the mains
- The update will start. After
approximately 4 minutes the TV will automatically restart.
- After restarting, perform the reset
by going to the settings menu “MENU (key) System Restore Mode
Factory. Confirmation and password
request is requested. Enter 1234 and press "OK".
- After this the TV will restart.
PROJECT ID CHANGE
(If panel information is wrong)
If the screen is completely dark due
to the difference in panel x installed ware, press 062598 + MENU + xxx (xxx:
Panel ID)
After the update, the TV will enter TV
mode and the channel that was previously selected. Enter the menu factory
settings again, select option 3 - Reset Shop, press enter.
After the reset, switch on the device
using the power key.
PANEL TEST MODE
(WARM-UP)
Recommended for analysis of panels
(spots, dots, scratches, etc.).
Enter the Factory Menu as indicated
before, turn on the "Factory hotkey" option and turn on the
"WARM-UP" function.
A sequence of screens in different
colors will be generated where it can be verified in more detail, possible
failures the panel.
VERIFICATION OF
AUTHENTICATION KEYS
In the same “WARM-UP” mode, a table
with the main product information will be displayed in the corner bottom right.
In this table we have the project
information:
We have the project ID, as shown in
the table above and then the version of the software in use.
Below the information of the recorded
keys (MID):
MAC (Mac Address) Without recording
this key, it is not possible to connect to the internet network via ethernet
(LAN);
DID (Device ID) Factory Control of the
product; Already included in the main ware.
ESN (Ne lix) Without the recording of
this key, it will not be possible to access the Ne lix services;
HDCP Without recording this key, high
definition images from the HDMI inputs will not be reproduced;
HDCP2.0 Without the recording of this
key, high definition images via wireless will not be reproduced;
IMPORTANT NOTE: If some of the keys
are not recorded, the information “NULL” will appear in substitution the
respective key in that line as shown in the image on the right.
In this case, SEMP TCL support should
be contacted for instructions on recording procedures.
To EXIT the “WARM-UP” mode, press the
POWER key on the device because the control functions remote will be disabled
and if the device is just disconnected from the network, the “WARM-UP” mode will
return when connected to the network again.
After exiting WARM-UP, enter the
factory menu again and turn off the Factory Hotkey option or give a user reset.
No comments: