Friday 9 February 2018

Star trac Pro Treadmill AC 7600 – 7700 – How to adjust the running belt tension – How to access Maintenance mode – Auto calibration

Star trac Pro Tread AC 7600 – 7700
RUNNING BELT RETENSION PROCEDURE 
Step 1: Release tension of running belt by unscrewing the tension screws until the roller touches the finger-guard. The belt should be completely relaxed.
(Note: This applies to both left & right fingerguards.)
Step 2: Apply a piece of masking tape on the edge of the running belt on both sides.
Step 3: Draw a line on each piece of masking tape aligned with the edge of the deck.
(Note: Be careful not to move the belt or roller while drawing the lines.)
Step 4: Check to make sure that both lines are aligned with the edge of the deck at the same point.
Step 5: Using a ruler or tape measure, draw a line on each piece of tape parallel to each first line at a distance of 3/8” (9.5mm) from each first line.
Step 6: You are now ready to begin tensioning the belt. Before beginning, make sure the line on each piece of tape closest to the tail roller is aligned with the edge of the deck on each side.
Step 6: Using the 1/4" Allen wrench begin tightening the tensioning screws (see Fig 1). You will tighten (or stretch) the run belt until the forward lines on the tape are aligned with the edge of the deck.
Be careful to ensure the Tail Roller does not turn while you are stretching the belt. If the Tail Roller turns while you are stretching the belt, start the procedure over. If the Tail Roller turns while stretching the belt you will not obtain proper tension.
When finished, remove the tape from the running belt.
MAINTENANCE MODE
The Maintenance Mode allows you to query and modify the settings of the Star Trac product.
Engaging Maintenance Mode
1.Press and hold the 2 + 3 + start keys.
2.While holding all three keys release the key 2 only.
A beep will sound and the display will read “MAINTENANCE MODE” momentarily in the information window.
3. Once in the Maintenance Mode release all of the keys.
The display will read “UNITS: ENGLISH” (or “UNITS: METRIC”) depending on your settings.
You will now be in the Maintenance Settings mode for you unit. As a safety precaution, the unit will only stay in the Maintenance Mode for approximately 45 seconds after the last key stroke entry. As long as you are adjusting settings or scrolling through parameters, the unit will stay in mode.
Maintenance Mode Keys
The following keys are used to search through and modify the Maintenance Settings:
INCLINE keys: Display the next and previous parameters.
SPEED keys: Adjust the value of the displayed parameter up and down respectively. Some parameters can utilize the number pad.
ALPINE PASS: Sets parameter back to its default factory setting. Note: For parameter “LAST DECK” this key will set the parameter to the current “MILEAGE” value to clear the “REWAX BELT” message.
OK key: Updates (saves) the value of the display setting in the memory.
START key: Used to initially enter the Maintenance Mode and updates changed parameter values.
NUMBER PAD: Used to directly enter numeric values.
STOP key: Used to exit the Maintenance Mode.
TEST MODES
Within the Maintenance Mode parameters are a few Test Modes that can be used to test various functions of the unit. While in the Maintenance Mode, set the following parameter and use the functions as listed to utilize each parameter.
DISPLAY TEST
The Display Test can be used to test each individual key for function and response, and can
also be used to verify led function and display
Press ‘Start’ key Display will enter DISPLAY TEST and await your next command
Press ‘Start’ key Display will cycle thru a self test and display all led’s in a sequenced pattern.
Press ‘Stop’ key twice to return to the MAINTENANCE MODE
Press ‘Start’ key Display will enter DISPLAY TEST and await your next command
Press ‘1’ key MC1 Vx.x CKSM xxxx will display
Press ‘Speed Plus’ key MC2 Vx.x CKSM xxxx will display
Press ‘Speed Minus’ key MC1 Vx.x CKSM xxxx will display
Press ‘Stop’ key twice to return to the MAINTENANCE MODE
Press ‘Start’ key Display will enter DISPLAY TEST and await your next command
Press ‘2’ key Display will read KEYBOARD TEST
Press any key except ‘Stop’ to verify function.
Press ‘Stop’ key to verify function then press again to return to the MAINTENANCE MODE
You can also access the Display Test right away when entering the Maintenance Mode:
When the display reads UNITS: ENGLISH (or UNITS: METRIC), press the ‘5’ key then follow the procedures above.
MOTOR TEST
This parameter is used by Star Trac at the factory.
*For MOTOR TEST MODE, see the MOTOR TEST MODE section of this manual.
BELT/DECK TEST
This parameter is used by Star Trac at the factory
CALIBRATE SCALE
Press ‘Start’ key Display will enter CALIBRATE SCALE mode and scroll the following:
1 = INPUT SPAN WEIGHT
2 = CAL SPAN WEIGHT
3 = CAL ZERO WEIGHT
4 = VERIFY WEIGHT
PRESS STOP TO EXIT
 > Loop
Pressing ‘Stop’ will return to MAINTENANCE MODE
Press ‘1’ key Unit will read REF WEIGHT = 155
Enter your exact weight *It is advisable to weigh yourself for accuracy just before performing this step.
After entering your weight press either the ‘Start’ or ‘OK’ keys.
Display will read : STEP ON WEIGHT PADS
PRESS OK TO BEGIN  > Loop
 Pressing ‘OK’ will read CALIBRATING X (X = your entered weight)
If no weight entered, unit will read:
CAN NOT CALIBRATE
NO WEIGHT ACQUIRED
PRESS OK TO RETRY
PRESS STOP TO EXIT
 >Loop
Pressing ‘OK’ will return to previous step
Pressing ‘Stop’ will return to MAINTENANCE MODE
Press ‘2’ key Display will read: PLACE CAL WEIGHT
ON WEIGHT PADS
PRESS OK TO BEGIN
 > Loop
After pressing ‘OK’ unit will read CALIBRATING X (X = calibrated weight)
If no weight entered, unit will read:
CAN NOT CALIBRATE
NO WEIGHT ACQUIRED
PRESS OK TO RETRY
PRESS STOP TO EXIT
 > Loop
Pressing ‘OK’ will return to previous step
Pressing ‘Stop’ will return to MAINTENANCE MODE
Press ‘3’ key Display will read: REMOVE WEIGHTS
PRESS OK TO BEGIN
After pressing ‘OK’ unit will read CALIBRATING X (X = weight zero)
If no load cells detected, unit will read:
CAN NOT CALIBRATE
NO WEIGHT ACQUIRED
PRESS OK TO RETRY
PRESS STOP TO EXIT> Loop
Pressing ‘OK’ will return to previous step
Pressing ‘Stop’ will return to MAINTENANCE MODE
Press ‘4’ key Display will read: WEIGHT= 0 and display the weight as detected
Press ‘Stop’ key once to return to the CALIBRATE SCALE mode
Press ‘Stop’ key a second time to return to the MAINTENANCE MODE
AUTO CALIBRATION
Electrical voltages vary between locations. The treadmill can run through an auto-calibration process to allow the electronics to balance out with the speed control.
To run an auto-calibration procedure, do the following:
Auto-Calibration
DO NOT LEAVE THE TREADMILL UNATTENDED WHILE RUNNING THE AUTO-CALIBRATION PROCEDURE AS IT WILL RUN THE BELT TO THE MAXIMUM SPEED SETTING.
1. Enter the Maintenance Mode (see “Engaging Maintenance Mode”). The display will read:
2. Enter the Motor test mode by pressing the ‘8’ key once. The display will read:
3. Start the auto-calibration process by pressing the ‘Forest’ key once and immediately stepping off of the treadmill.
The center number (3) will begin to increase, running belt will move and the center number will on the right hand side of the display (0.0) will move .
The treadmill running belt will begin to move:
Running belt will move, center number will increase and the numbers on the right hand side of the display ‘0.0’ will move.


LG 52LG50FD, 52LG50FD-SA-Service adjustments-service mode entry-white balance adjustment-ADC component 1 RGB adjustment and more

  These adjustments are similar to 42LB7DF Because this is not a hot chassis, it is not necessary to use an isolation transformer. However...