Friday, 13 October 2017

Matrix fines treadmill - Matrix T5x-07 – Auto calibration procedure - How to access manager mode – How to access service mode – Error code and troubleshooting

Engineering mode
1. To enter Engineering Mode, hold the INCLINE DOWN and SPEED DOWN keys for three seconds until Manager Mode appears on the middle LED display.
2. Press any UP arrow key and Engineering Mode will appear on the display.
3. Press ENTER once Engineering Mode is displayed.
4. To scroll between programs in the Engineering Mode, press any UP or DOWN arrow key.
5. Press ENTER to modify the program settings once displayed.
6. Press any UP or DOWN arrow key to change value.
7. Once program setting is correct, press ENTER to save.
8. Press the EMERGENCY STOP to exit Engineering Mode
Service mode
1. To enter Service Mode, hold the INCLINE DOWN and SPEED DOWN keys for three seconds until Manager Mode appears on the middle LED display.
2. Press any DOWN arrow key and Service Mode will appear on the display.
3. Press ENTER once Service Mode is displayed.
4. To scroll between programs in the Service Mode, press any UP or DOWN arrow key.
5. Press ENTER to modify the program settings once displayed.
6. Press any UP or DOWN arrow key to see value.
7. Press the EMERGENCY STOP to exit Service Mode
Auto Calibration Procedure:
1) Press and hold the INCLINE DOWN and SPEED DOWN keys for three seconds until Manager Mode appears on the middle LED display.
2) Press any UP arrow key and Engineering Mode will appear on the display.
3) Press ENTER once Engineering Mode is displayed.
4) Scroll between programs in the Engineering Mode using any UP or DOWN arrow key until Auto Calibration appears on the middle LED display.
5) Press ENTER once Auto Calibration is displayed. You should not be standing on the running belt.
6) After completion, the display will state whether the Auto Calibration passed or failed.
Manager mode
1) To enter Manager Mode, press & hold INCLINE DOWN and SPEED DOWN at the same time for 3-5 seconds until Manager Mode appears on the display.
2) To enter the Manager Mode, press ENTER once Manager Mode appears on the display.
3) To scroll between programs in the Manager Mode, press any UP or DOWN arrow key.
4) Press ENTER to modify the program settings once displayed.
5) Press any UP or DOWN arrow key to change value.
6) Once program setting is correct, press ENTER to save.
7) Press the EMERGENCY STOP to exit Manager Mode.
Error messages 0140 / 01a0 / 01a2
1) symptom:
a. 0140 - Incline motor operation failed.
b. 01A0 - Incline motor disconnected.
c. 01A2 - Incline motor is detected in the reverse of the position indicated by the potentiometer.
2) Solution
a. Check the connection of the incline motor cable at the MCB.
b. Run auto calibration
c. If auto calibration fails, re-enter Engineering Mode and scroll until Elevation Minimum is displayed, then press ENTER.
- Check the MCB LEDs. If  LED (DOWN )has no light, check the console cable connections at the console and MCB.
Replace the console or cable as needed. If LED DOWN has a light, replace the incline motor.
d. If the incline motor does not resolve the issue, replace the MCB.
Error message 01a3
1) symptom:
a. Motor is disconnected.
2) Solution:
a. Check the connection of the motor cable at the MCB
b. Check to see if the MCB LED DSP1 (MCU) is lit.
c. If LED DSP1 is blinking, the motor should be replaced.
d. If LED DSP1 is a solid light, replace the motor.
e. If LED DSP1 is not lit, replace the MCB
Error message 01a8 / 02b6 / 02b7 / 02b8
1) symptom:
a. 01AB - Motor over current.
b. 02B6 - Speed up is overcurrent.
c. 02B7 - Speed down is overcurrent.
d. 02B8 - Running status is overcurrent.
2) Solution:
a. Check the condition of the running deck and belt. Replace the belt and flip or replace the running deck as needed.
b. Replace the MCB.

Error message 02b9 / 02ba / 02bd
1) symptom:
a. 02B9 - The inner memory IC data write error.
b. 02BA - The inner memory IC data read error.
c. 02BD - Inverter hardware interrupt error.
2) Solution:
a. Check LED DSP1 (MCU) on the MCB.
b. If this LED is blinking, replace the console.
c. If this LED is a constant light, replace the MCB.
d. If this LED is not lit at all, check the power to the MCB.

LG 52LG50FD, 52LG50FD-SA-Service adjustments-service mode entry-white balance adjustment-ADC component 1 RGB adjustment and more

  These adjustments are similar to 42LB7DF Because this is not a hot chassis, it is not necessary to use an isolation transformer. However...